Tower UPS
Application:
PC, ATM machine, server, network, radio and television, microcomputer room, bank securities network, signal station, mobile base station.
| Delivery Time | |
|---|---|
| Supply Capacity |
Feature:
● Advanced work mode DSP digital control Technology, high performance.
● Protection of comprehensive and reliable it can effectively solve 9 power problems such as power failure, surge, transient, spike, etc.
● The design of optimizing battery pack 1KVA-24VDC/36VDC(optional), 2KVA-48VDC/72VDC(optional) and 3KVA-72/96VDC(optional).
● Function of the charger extension charging current is 1-4A, support extended to 6A.
● Strong adaptability to environment overload capacity is 120%.
● Intelligent management RS232/USB are optional.
● Overload capacity: 105%-125%, 1mins; load>125%,30s turn to bypass output; load>150%,300ms turn off.
Technical Parameter:
|
Model |
BK-U1101B |
BK-U1101H |
BK-U1102B |
BK-U1102H |
BK-U1103B |
BK-U1103H |
|
|
Capacity |
1000 VA / 900 W |
2000 VA / 1800 W |
3000 VA / 2700 W |
||||
|
Input |
Voltage |
110 – 300 VAC (Auto sensing) |
|||||
|
Power Factor |
0.99 (nominal output @ full load) |
||||||
|
Frequency |
46Hz ~55 Hz or 56Hz ~ 64 Hz |
||||||
|
Phase |
Single phase with ground |
||||||
|
Output |
Voltage |
200/208/220/230/240 VAC |
|||||
|
AC Voltage Regulation (Static) |
± 1% |
||||||
|
Frequency Range |
48~ 52 Hz or 58 ~ 62 Hz (Synchronized Range) 50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz (Batt. Mode) |
||||||
|
Current Crest Ratio |
3:1 |
||||||
|
Harmonic Distortion |
2 % THD (Linear Load),≦ 6 % THD (Non-linear Load) |
||||||
|
Waveform (Batt. Mode) |
Pure sinewave |
||||||
|
Output Factor |
0.8 / 0.9 |
||||||
|
Transfer Time |
AC Mode to Batt. Mode: 0 ms; AC Mode to Bypass: 4 ms (Typical) |
||||||
|
Efficiency (Peak) |
AC Mode (@100% RCD load): 88% Battery Mode (@100% RCD load): 83% |
||||||
|
Battery |
Type |
12V / 9Ah |
|||||
|
Battery Numbers |
2 |
External |
4
|
External |
6
|
External |
|
|
Typical Recharge Time |
5 hours recover to 90% capacity |
||||||
|
Charging Current |
1A |
||||||
|
Charging Voltage |
27.4 VDC ± 1% |
54.8 VDC ±1% |
82.2 VDC ±1% |
||||
|
Indicators |
LED / LCD Panel: UPS status, Load level, Battery level, and Fault conditions |
||||||
|
Environment |
Working humidity: 20-95 % RH @ 0- 40°C (non-condensing); Noise Level: Less than 50dBA @ 1 Meter |
||||||
|
Alarm |
Battery Mode: Sounding every 4 seconds Low Battery: Sounding every second Overload: Sounding twice every second Fault: Continously sounding |
||||||
|
Optional SNMP |
Communication: RS232 Card / Optional USB Card, SNMP Card, or AS400 Card available; Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7, Linux, Unix, and MAC. Optional SNMP: Power management from SNMP manager and web browser. |
||||||
|
External Size(W*D*H) mm |
145*350*228 |
145*350*228 |
190*395*328 |
190*395*328 |
190*395*328 |
190*395*328 |
|
|
Package Size(W*D*H) mm |
236*428*333 |
236*428*333 |
325*493*458 |
325*493*458 |
325*493*458 |
325*493*458 |
|
|
Net weight (kg) |
9.6 |
4.9 |
17.5 |
8.3 |
23 |
8.9 |
|
|
Gross weight (kg) |
10.7 |
6.2 |
19.1 |
9.6 |
25 |
10.3 |
|
* If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
* When the temperature is lower than 30°C, the power factor can be adjusted to 0.9.
Related
Our company strives to provide efficient and reliable shipping services to ensure that your order arrives in a timely manner. We work closely with our logistics partners to ensure that your package is picked up, processed, and delivered with the utmost care and attention. Rest assured that we use only reputable shipping carriers with proven track records for on-time delivery and safe handling of packages. Upon confirmation of your order, we will provide you with a tracking number so that you can monitor the progress of your shipment. We appreciate your business and look forward to serving you!